low voltage

Hotline

MTL3014 SWITCH/ PROXIMITY DETECTOR RELAY dual outputs has been discontinued.

description:MTL3014 SWITCH/ PROXIMITY DETECTOR RELAY dual outputs has been discontinued for sale....
BASIC INFO
MTL3000 series MTL3014 SWITCH/ PROXIMITY DETECTOR RELAY dual outputs has been discontinued  for sale.
MTL3000 Series interface units offered a compact and easy-to-use means for communicating safely with process measuring, indicating, actuating and local control equipment in hazardous areas. The comprehensive range of models included analogue, switch and serial-digital signals in both directions, amplifying or otherwise conditioning them as required and at the same time providing world wide certified explosion protection for equipment and wiring in all zones and all explosive atmospheres. It also provided an alternative to the shunt-diode safety barrier where isolation was essential or preferred or a high-integrity earth was not readily available.
 
The MTL5500 Series are the recommended replacements for this series.

MTL3014 SWITCH/ PROXIMITY DETECTOR RELAY dual outputs.
The MTL3014 enables two safe-area loads to be controlled by a single proximity detector or switch located in a hazardous area. It is
ideal for applications where the switch status is to be fed to two separate systems, such as control and logging or control and
shutdown installations. The unit – a dual-output version of the MTL3011 – features two isolated relay outputs. Relay A reflects the
status of the hazardous-area sensor, and relay B is selected by aswitch in the top of the unit to operate either in parallel with relay A,
or independently to provide a line-fault output when the connections to the sensor go open or short circuit. The status of each relay is indicated by an LED in the top of the unit, and an additional terminal block is fitted on the safe-area side of the unit to accommodate the connections from the two sets of relay contacts. The output phase of relay A (and relay B when ‘slave’ mode is selected) can be reversed by a link to allow an alarm condition (output open) to be signalled for either state of the sensor. The outputs cannot be used as if they were changeover contacts from a relay.
 
MTL3000 series
Product CodeDescription
MTL3011   Switch/proximity detector relay - volt-free contacts
MTL3012   Switch/proximity detector relay - solid state 
MTL3013   Switch/proximity detector relay - 2-channel 
MTL3014   Switch/proximity detector relay - dual outputs
MTL3021_22  Solenoid/alarm driver ~ IIC loop powered
MTL3041   Repeater power supply - 4/20mA for 2-wire transmitters 
MTL3042   DC isolator - 4/20mA loop powered for I/P converters
MTL3043   DC isolator - 1/40mA for fire and smoke detctors
MTL3045   Isolating driver - 4/20mA for I/P converters 
MTL3046B  Repeater power supply - for ‘smart’ transmitters
MTL3052   Digital isolator - for signals up to 10kHz
MTL3054   Communications isolator/ repeater
MTL3058_59  Serial data interface ~ RS232 general purpose
MTL3071   Temperature converter ~ THC or emf input
MTL3072   Temperature converter ~ 3-wire RTD input
MTL3073   Temperature converter ~ THC or RTD input
MTL3081   Millivolt isolator - for low-level inputs
MTL3099   Dummy isolator - for terminating and isolating unused cores 
MTL3992   High stability power supply

Pre:MTL3013 SWITCH/ PROXIMITY DETECTORRELAY 2–channel has been discontinued. Next:MTL3000 series MTL3021 – IIC, loop powered safety barrier has been discontinued.